The first medical high intensity cyclotron CYCIAE-30 and its beam line for the isotope production were built in 1994 at China Institute of Atomic Energy.Now,an upgrading beam line system is designed based on the existing beam line of CYCIAE-30 to transport the beam extracted from the cyclotron to a gas target for the new isotope production,including elements location design,optics simulation and magnet design.The machining and installation of all the elements are accomplished based on the design.The beam tuning is finished and the transmission of 96.5% is obtained.
In a cyclotron,the RF cavity is the key device to accelerate ions.The RF cavity design for the 100MeV H^- cyclotron is very complex since the space is narrow and the Dee voltage is 60kV at the center and 120kV at the extraction region.CST MICROWAVE STUDIO is used in the design,and a real model has been made.The test result on the model is in good agreement with the simulation result.