In this paper, the boundary value problem (BVP) of 3 D transient eddy current field in the end region in the case that the generator is affected by impact load is specified. Besides, ways to implement discrete methods in both time domain and space domain during the solution of the problem are investigated. The Crank Nicolson scheme is utilized to attain the iterative format of time differential, after taking factors that can ensure both computation precision and stability into consideration. In this paper, the magnetic distribution in the end region of a turbogenerator in the case that the generator is affected by impact load is specified. As a result, it provides foundation for further study of electromagnetic force and electromagnetic vibration in the end region of the turbogenerator.